Cisco Systems 694 Benutzerhandbuch

Seite von 84
C H A P T E R
 
6-1
Cisco Wide Area Virtualization Engine 594 and 694 Hardware Installation Guide
OL-24619-02
6
Troubleshooting the System Hardware
This chapter provides basic troubleshooting information to help you identify some common problems 
that might occur with your WAVE-594 and WAVE-694.
This chapter contains the following sections:
  •
  •
  •
  •
  •
  •
Use the information in this chapter to determine whether a problem originates with the hardware or the 
software. For further assistance, contact your Cisco customer service representative.
Note
When console redirection is enabled (it is disabled by default), all the tests available from a keyboard 
are accessible through the console connection as well. (Mouse support, however, is not available through 
the console connection.)
Caution
Customer-replaceable components include the WAVE Interface Modules, hard disk drives, power supply 
assemblies, fans, and memory. All other components that are not orderable as spare hardware options 
can only be replaced by a qualified service technician. Once you have identified a faulty component, 
contact the Cisco Technical Assistance Center (TAC). 
Identifying System Problems
To identify system problems, follow these steps:
Step 1
Check the power LED.
Step 2
Check the system fault LED (see 
). If the status is yellow, check for alarms 
using the show alarms command.
Step 3
Power down the appliance and all external devices.
Step 4
Check all cables and power cords. (See the