B&B Electronics 232SDD16 Benutzerhandbuch

Seite von 27
232SDD16-1005 Manual 
23 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815) 433-5104
 
Step 5 - Determining the I/O line definitions: 
MSdefs = MSdefs AND mask 
LSdefs = LSdefs AND mask
 
By "ANDing" the value of MSdefs or LSdefs with the appropriate 
mask of an I/O line, the I/O line definition can be determined.  If 
the status is equal to zero the I/O line is an INPUT. If the status is 
not equal to zero the I/O line is an OUTPUT.  Table 5.1 shows 
the mask values for each I/O line. 
Step 6 - Repeat Step 5 until the status of each I/O line has been  
determined. 
Step 7 - Determining an OUTPUT's Power-up state: 
MSpups = MSpups AND mask 
LSpups = LSpups AND mask
 
By "ANDing" the value of MSpups or LSpups with the 
appropriate mask of an Output line, the Output line definition can 
be determined.  If the status is equal to zero the Output power-up 
state will be LOW. If the status is not equal to zero the Output 
power-up state will be HIGH.  Table 5.1 shows the mask values 
for each I/O line. 
Step 8 - Repeat Step 7 until the power-up state of each Output line 
has been determined. 
 
Example 5.2 - Determining the definition and power-up state of I/O 
lines #2 & #10 
mask = &H4 
Cmnd$ = "!0RC" 
PRINT #1, Cmnd$; 
MSdefs$ = INPUT$(1,#1) 
LSdefs$ = INPUT$(1,#1) 
MSpups$ = INPUT$(1,#1) 
LSpups$ = INPUT$(1,#1)
 
MSdefs = ASC(MSdefs$) 
LSdefs = ASC(LSdefs$) 
MSpups = ASC(MSpups$) 
LSpups = ASC(LSpups$) 
MSdefs = MSdefs AND mask 
LSdefs = LSdefs AND mask 
MSpups = MSpups AND mask 
LSpups = LSpups AND mask 
 
24 232SDD16-1005 
Manual 
 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815) 433-5104
 
If LSdefs equals zero then I/O line #2 is an INPUT and if not equal 
to zero then I/O line #2 is an OUTPUT.  If MSdefs equals zero then 
I/O line #10 is an INPUT and if not equal to zero then I/O line #10 is 
an OUTPUT.  If LSpups equals zero then Output line #2's power-up 
state is LOW and if not equal to zero then Output line #2's power-up 
state is HIGH.  If MSpups equals zero then Output line #10's power-
up state is LOW and if not equal to zero then Output line #10's 
power-up state is HIGH. 
 
Set Output States Command 
Step 1a - Construct the command string: 
Set appropriate outputs HIGH 
MSstates = MSstates OR mask 
LSstates = LSstates OR mask
 
By "ORing" the current states with the appropriate mask of a 
digital output line, the output's bit will be set to a "1" (HIGH). 
Step 1b - Set appropriate outputs LOW 
MSstates = MSstates AND (NOT(mask)) 
LSstates = LSstates AND (NOT(mask))
 
By "ANDing" the current states with the complement of the 
appropriate mask of a digital output line, the output's bit will be 
set to a "0" (LOW). 
Step 1c - Completing the command string: 
Cmnd$ = "!0SO" + CHR$(MSstates) + CHR$(LSstates) 
Step 2 - Transmitting the command string: 
Print #1, Cmnd$; 
 
Example 5.3 - Set Output #0 HIGH and Output #14 LOW. 
'Set bit 0 of LSstates to make Output #0 HIGH. 
LSstates = LSstates OR &H1 
'Clear bit 4 of MSstates to make Output #14 LOW. 
MSstates = MSstates AND (NOT(&H40)) 
Cmnd$ = "!0SO" + CHR$(MSstates) + CHR$(LSstates)
 
PRINT #1, Cmnd$; 
MSIO$ = INPUT$(1,#1) 
Output #0 will be set HIGH and output #14 will be set LOW.  All 
other output setting will not be changed.