B&B Electronics ES1AWB Benutzerhandbuch

Seite von 58
  
Getting 
Started 
Manual Documentation Number: ES1AWB-2907m    
pn6908-rev003
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
 
Chapter 
       11 
If you are configuring your own access point (a wireless switch or 
router) ensure that it is configured as a DHCP server with the 
Wireless Network Name (SSID): Connect 
4. Get the IP Address 
‰ 
Use the discovery software on your CD (finder.exe) to get the IP 
address for your ES1AWB 
5. Login 
‰ 
In a web browser on your PC, type in the IP address and access the 
Web Configuration and Management Interface 
‰ 
Login using the username ‘root’ and password ‘dbps’ 
6. Configure the ES1AWB 
‰ 
In the Configuration, Network page configure your Wireless LAN, 
Security and other settings required to work on the type of wireless 
network you will be connecting to. 
‰ 
In the Configuration, Serial Ports page select the Port Profile you 
require for use with your application (E.g. RealPort for virtual COM 
port, TCP Server, UDP server, Serial Bridge, etc) 
‰ 
Configure the serial port settings for the selected Port Profile (e.g. In 
TCP Sockets select client or server, TCP port numbers, etc. Also 
configure baud rate, data bits, etc in Basic Serial Settings. 
‰ 
Configure any required alarms and notification 
‰ 
If RealPort profile was selected (virtual COM port) do the next step 
(Set up VCOM) 
7. Set up VCOM (if using the RealPort profile) 
‰ 
Start the RealPort software wizard (located on the included CD) 
‰ 
Select Add a New Device 
‰ 
Select your ES1AWB from the list  
‰ 
Select an unused COM port number 
‰ 
Follow the wizard to set up a virtual COM port 
8. Communicate 
‰ 
Configure and then start your application