Chapter 6:  Physical Hook-up and Troubleshooting 
 
 
This chapter will cover 3PXCC pinout, communication cable 
data, and troubleshooting information. 
Pinouts 
RS-232 Pinouts 
 
The 3PXCC Serial Cards are wired as DTE (Data Terminal 
Equipment) devices. The 3PXCC Serial Cards can be connected 
directly to DCE (Data Communication Equipment) devices with a 
straight through cable. If you need to connect two DTE devices, you 
will need a null modem cable or cross-over cable. 
 
Table 5.  RS-232 Pinout Description 
 
RS-422 Pinouts 
 
RS-422 mode supports transmit and receive data signals.  
The pinouts of the DB-9 connector are given in Table 6. Figure 5 
shows how to connect a typical RS-422/RS-485 full duplex 
communication link. 
 
 
Pin Name 
Description 
Direction 
DCD Data 
Carrier 
Detect  input 
     2 
RD Receive 
Data 
input 
TD Transmit 
Data 
output 
DTR Data 
Terminal 
Ready 
output 
GND Signal 
Ground 
------ 
DSR Data 
Set 
Ready 
input 
RTS 
Request to Send 
output 
CTS Clear 
to 
Send 
input 
RI Ring 
Indicator 
input 
40  
Documentation 
No.3PXCC1x-2x-3903 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 
Pin Name Description 
RD(A) 
Receive Data A 
2 TD(B) 
Transmit 
Data 
3 TD(A) 
Transmit 
Data 
5 GND 
Signal 
Ground 
RD(B) 
Receive Data B 
Table 6. RS-422/RS-485 Pinout Description 
RS-485 Pinouts 
 
RS-485 mode supports both full and half duplex 
communications (transmit and receive data signals). The pinouts of 
the DB-9 connector are given in Table 6 (if full duplex 
communication is used). Figure 5 shows how to connect a typical 
RS-422/RS-485 full duplex communication link. Figure 6 shows how 
to connect a typical RS-485 half duplex communication link.  
 
Figure 5. RS-422/RS-485 (Four Wire) Pinout Description 
 
 
 
 
 
 
TD(A-) Pin 3
TD(B+) Pin 2
RD(A-) Pin 1
RD(B+) Pin 9
GND Pin 5
TD(-)
TD(+)
RD(-)
RD(+)
GND
3PXCCXX Serial Card
RS-422 Four Wire Devic