B&B Electronics HVD100A3 Benutzerhandbuch

Seite von 31
HDV100A3 Command & Response Manual-1306cr 
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 
PH (815) 433-5100 -- FAX (815) 433-5104
 
Baud Rate Example 
 
To set the PC baud rate to 57,600 baud, N,8,1, format the message as 
follows. 
 
Byte 
Number 
Byte 
Value 
Hex 
 
Byte Function 
 
01 
 
Start of frame 
 
05 
 
Number of control bytes 
 
3 08 
 
Command byte (08 = internal command) 
 
4 01 
 
Function Bbte (01 = change baud) 
 
5 03 
 UB3 
 
6 08 
 Baud 
 
7 00 
 Baud 
 
00 
 
Number of data bytes 
 
9 1A 
 Checksum 
 
 
The first byte is the start of frame and always 01. Next is the 
number of control bytes (05). There are 5 bytes in the control section (in 
gray). Byte number 3 sets the HDV100A3 to an internal operation (08). Byte 
4 is the internal function to be executed; (01) is the change baud command. 
Bytes 5, 6, and 7 set the baud rate, parity, stop bits and word length. Next is 
the number of data bytes, in this case there are no data bytes. Last is the 
checksum, the value is the 8 bit addition of bytes 1 to 8.