J1708 Commands 
 
Receiving Data from the J1708 Bus 
 
 
After the HDV100A3 is set into its Intelligent mode of operation 
and the RS-232 data rate is configured, you are now ready to communicate 
with the J1708 bus. A receive command must be sent to the HDV100A3 
before attempting to transmit to the bus. The receive message synchronizes 
the HDV100A3 with the bus. To start receiving J1708 bus data, send the 
following to the HDV100A3.  
 
Byte 
Number 
Byte Value  
 (hex) 
Byte Function 
01 
Start of frame 
02 
The number of control bytes 
01 
ID byte 01= J1708  
11 
Function code 11 hex start receive 
00 
Number of data bytes (00 place holder) 
15 
Checksum (bytes 1 through 5 added together) 
 
After sending this command to the device, the device will respond 
with a confirmation message. The message confirms that the command was 
received by the HDV100A3 and the checksum verified correctly. The reply 
from the device is formatted as follows: 
 
Byte 
Number 
Byte Value 
 (hex) 
Byte Function 
01 
Start of frame byte 
2 01  Control 
byte 
01 
ID byte (ID of the sent message) 
00 
Number of data bytes 
5 03  Checksum 
 
 
The confirmation message is sent in response to a command sent to 
the device. The ID byte and the check-sum will change with different 
commands but the format will remain the same. If the checksum is not 
correct an error message is sent. Its format is covered at the end of this 
document. 
 
To stop receiving data from the J1708 bus send the following 
command to the HDV100A3.