B&B Electronics HVD100A3 Benutzerhandbuch

Seite von 31
24 
HDV100A3 Command & Response Manual-1306cr 
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 
PH (815) 433-5100 -- FAX (815) 433-5104
 
The mask can be used to look at a group of messages: 
To set the mask to filter on the J1939 priority field, the mask would be 
loaded with: 
(01, 06, 02, 04, E0, 00, 00, 00, 00, ED) 
To set the mask to filter on the J1939 PGN field, the mask would be loaded 
with:  
(01, 06, 02, 04, 07, FF, F8, 00, 00, 0B) 
To set mask to filter on both the priority field and the PGN field the mask 
would be loaded with: 
(01, 06, 02, 04, B7, FF, F8, 00, 00, BB) 
 
Set Filter 1 to 4 
 
Function codes 18 and 19, 28 and 29, 38 and 39, 48 and 49 are filter pairs. 
These filters are set by sending the desired arbitration code to each filter, 1 
to 4. The filters work with the mask function. If the mask is set to zero in a 
position (don’t care) the value of the filter in that position doesn’t matter. 
The filter arbitration field is set to match the aberration code of the incoming 
message. A match of the filter “and” the mask will pass the message to the 
PC. The X9 sets the filter On; X8 sets the filter Off, where X=1 through 4. 
Important:
 the receiver and each filter must have a different arbitration 
code. If the receiver and a filter are given the same arbitration code the 
controller may become erratic. It will need to be powered-off reset to 
recover from this error. 
 
 
Byte  
Number 
Byte 
Value 
Function 
01 
Start of Frame 
2 06 
Control 
bytes 
02 
ID byte = J1708 message 
YY 
Function byte (18 or 19) (28 or 29) (38 or 39) (48 or 49) 
XX 
MSB of arbitration field (J1939 priority bits) 
6 XX 
MSB-1 
7 XX 
MSB-2 
XX 
LSB of arbitration field (J1939 source address) 
00 
Number of data bytes 
10 CS 
Checksum 
 
To use the HDV100A3, the filter for a particular J1939 PGN the following 
procedure must be followed. 
 
 
1. Turn off the “Receive” function by sending (01, 02, 02, 00, 00, 05).