Black Box 945 Benutzerhandbuch

Seite von 28
20
WATLOW Series 945
How to Use Data Communications
Commands
Data.1
Data.2
Low Limit
High Limit
Code
Function
LATX
0
1
0
Latched alarms
1
Non-latched alarms
LINE
10
127
Lines per page for data logging
LOC
0
3
Lock front panel
LOG
0
3
0
Logging OFF See Page 22.
1
Table
2
Chart
3
SPCA
4
SPCd
5
SPCn
L-R
0
1
0
Local set point
1
Remote set point
LSL
rL USL Lower -2
°
F/-1
°
C
SPC lower spec limit
MAN
-100
100
Manual % output
MIN
0
59
Minute for data logging
MON
1
12
Month for data logging
OTX
0
1 or 2*
0
Heat
1
Cool
2*
No action
*only applies to Ot2
OT4
0
2
0
Output 4 = Process Retransmit
1
Output 4 = Set Point Retransmit
2
No action
PBX
0
999
°
F
Proportional Band
555
°
C
dFL = US
999 Units
PBX%
0.0
999.9
Output X proportional
band DFL = SI
RAX
0.00
9.99
Rate
REX
0.00
9.99
Reset
RH
Min. IN range
Max. IN range
Range High
RL
Min. IN range
Max. IN range
Range Low
RSP
0
2
0
OFF
1
0-5
2
420
RTD
0
1
0
DIN
1
JIS
SIL
0
1
0
Alarm silence OFF
1
Alarm silence ON
SPX
rL
rH
Set point
TAG
0
7
0
- - - = no logging
1
- - A
2
- S -
3
- SA
4
P - -
5
P - A
6
PS -
7
PSA
tbS
1
60
SPC time interval in minutes
USL
LSL Upper 2
°
F/1
°
C
rH
SPC upper spec limit
YEAR
0
99
Year for data logging
l
  
NOTE:
An X means it
applies to either
Output 1 or
Output 2.
Table 6 -
Continued
  
NOTE:
P = Process
S = Set Point
A = Alarm Set Point