3com 7600 Benutzerhandbuch

Seite von 210
Update Bridge-wide STP Parameters
6-25
Example
Enter: 
[3] [4] [2] [4] 0 2000
The bridge-hello-time for bridge #0 is set to 2000 secs.
Update
Bridge-forward-
delay
Update the STP parameter bridge-forward-delay for a specified bridge.
Example
Enter: 
[3] [4] [2] [5] 0 1500
The bridge-forward-delay for bridge #0 is set to 1500 secs.
Table 6-33   Task Actions
Menu 
Sequence
Enter
Result
[3] bridge 
[4] stp
[2] bridge
[4] hello
Bridge number {0-3}
Bridge-hello-time
The STP parameter 
bridge-hello-time for this bridge 
is updated.
Table 6-34   Task Actions
Menu 
Sequence
Enter
Result
[3] bridge 
[4] stp
[2] bridge
[5] forward
Bridge number {0-3}
Bridge-forward-delay
The STP parameter 
bridge-forward-delay for this 
bridge is updated.
abtthgde.book  Page 25  Tuesday, June 23, 1998  10:29 AM