Siemens EN 50295 Benutzerhandbuch

Seite von 152
Siemens IK PI · 2004
6/19
AS-Interface
AS-Interface Safety at work
AS-Interface light curtains and light arrays
for Category 4
6
Overview
 
The light curtains and light arrays of Category 4 acc. to EN 954-
1 offer active optical protection for persons at machines. They 
can be connected to AS-Interface directly and safely as an op-
tion.
SIGUARD light curtains and light arrays are
• active opto-electronic protective devices (AOPD), 
• comply with Type 4 acc. to EN 61496-1, -2, 
• are EU prototype-tested, 
• protect the operating personel working on or near dangerous 
machines, 
• operate contact-free, 
• are free of wear in comparison to mechanical systems (e.g. 
safety mats). 
For further details, see the manual "Safety Integrated“ and the 
operating instructions for the respective devices.
Benefits
• Double-scan function 
• Cascading of host and guest devices
• Two transmission channels
Design
A SIGUARD Light Curtain or light array comprises a transmitter 
and a receiver that must be mounted opposite each other. 
Depending on the resolution and length, a specific number of 
transmit and receive diodes are arranged in a vertical row. 
The infra-red LEDs of the transmitter send short light pulses that 
are received by the receive diodes.
SIGUARD Light Curtains:
• Resolution 14, 30 and 50 mm, 
• Length 150 mm to 3 m, 
• Cascading of master and slave devices to create larger height 
or length of protective zone or for angular arrangement. 
SIGUARD Light Arrays:
• 2-, 3- or 4-beam for access protection. 
Standards
• EN 61 496-1, -2, IEC 61 496-1, -2 (requirements for non-contact 
protection systems) 
• EN 999 (incl. calculation of safety clearances) 
• EN 954-1 (safety of machines, safety-related parts of controls).