Command Descriptions, 
Continued
 
 
reset 
This command resets and saves the configuration parameters in non-
volatile memory. 
 
test 
This command places a selected port into a hardware diagnostic mode. 
The test mode can be used to verify cable continuity and DataNET signal 
levels when used in conjunction with an Oscilloscope or other test 
device. 
The command: 
test 1 
places port 1 into test mode. The device will generate poll messages on 
port 1 every 50 milliseconds. The other port continues to operate 
normally. The command:  
test off 
turns off test mode. Only one port at a time may be in test mode. 
 
timeout 
This command may be used to disable the user login timeout. Normally, 
if a user has not issued a CLI command for five minutes, the device will 
automatically shut down the user’s login session. This command may be 
used to defeat (and re-enable) this timeout: 
timeout off 
Disables timeout. The device will not automatically 
log out the user; regardless of the time elapsed since 
the user last issued a CLI command. 
timeout on 
Re-enables the five-minute CLI timer. 
 