The attachment of both units is achieved by sliding them over the DIN rail
with the clip assembly pulled out and then releasing it when correctly posi-
tioned.
The 24V supply source should possess the following characteristics:
Because of power limitations, it should be noted that although up to 11
SMART-Modules are possible in a complete configuration, attention should
be paid to the following tables that show the individual component power
requirements. The maximum of 6750mW should not be exceeded as damage
to the on-board DC-DC converter may result due to overheating or entering a
reset status due to the thermal cutoff protection switching mechanism.
V o l t a g e
Current
min
m a x
Continuous
P e a k
18V
36V
400mA
1.5A (2ms)
S M - B A S E Power Consumption
min
m a x
CPU Core 1500mW 
1700mW
Profibus
250mW   
750mW
Module
Power Consumption
Module
Power Consumption
 min
m a x
 min
m a x
SM-DIN1
5mW 
100mW
SM-ADC1
350mW 450mW
SM-DOUT1
5mW
270mW
SM-DAC1
5mW
400mW
 
SM-DAD1
350mW
450mW
SM-DAC1
350mW
660mW
 
SM-PT100
400mW
500mW
SM-SSI
unknown
unknown
SM-THERM
400mW
500mW
   
SM-RS232
23mW
75mW
   
SM-REL1
23mW
160mW