APPLICATION 
 
When installed in forced air heating and cooling systems, the V-Flex kills airborne and surface 
microorganism contaminants.  It is designed to be mounted in-duct for airborne, “on-the-fly” 
applications as well as surface irradiation applications.  The design allows for many different 
levels of UV dosage.  Proper dosage is affected by many factors, such as air temperature, 
velocity, and duct reflectivity.  The space between supports (typically 32”) and the space between 
rows (typically 24” for surfaces and 12” to 18” for moving air streams) can be increased or 
reduced to adjust for dosage.   
 
See your Altru-V dealer or sales representative for assistance, as required.  
 
INSTALLATION 
 
1.  Read these instructions carefully.  Failure to follow the instructions could damage the 
product or cause a hazardous condition. 
2.  Check the electrical rating given in the instructions and on the product to make sure the 
product is suitable for your application. 
3.  To avoid accidental exposure to ultraviolet light, the power supply to this product 
must be electrically interlocked.  Interlock switches must be installed at any 
access panel or door within view of the UV fixtures. 
 
4.  The installer must be a trained, experienced service technician. 
5.  After installation is complete, check out product operation as provided in this guide. 
6.  If the HVAC system has been in use prior to installation, it is recommended that debris 
and buildup on coils and HVAC system surfaces be cleaned. 
 
Product Registration 
Thank you for purchasing this product from UVDI!  Prior to any other installation activities, 
please proceed with registering you product via the web at 
http://www.altruv.com
 or by 
returning the enclosed self-addressed postcard.  Product registration will insure that your 
warranty is handled in a proper and expeditious manner.  In addition, it will allow UVDI to 
provide you with important updates regarding your new product including reminders of 
when replacement parts are needed and also make you eligible for future parts discounts 
 
 
CAUTION 
 
Personal Injury Hazard 
Power supply can cause electrical shock.
 
 
Disconnect power supply before beginning installation.  Do not open lamp knob.  There are no 
user serviceable components inside.  Professional installation is required per NEC standards
 
WARNING 
 
UV Light Hazard 
Harmful to bare skin and eyes. 
Can cause temporary or permanent loss of vision.