NEC NDA-24233 Benutzerhandbuch

Seite von 124
Page 1-4
NDA-24233 Issue 2
Chapter 1
VisuaLink 128/384 Engineering Guide
Command Format
Command: Transmit 4-character commands (only upper case can be used)
Space:
More than one space is transmitted between a command and a parameter
Parameter: If a command requires a parameter, a parameter is assigned. (Only upper case can be used)  
However, if parameters are more than one, more than one space is transmitted between parameters.
CR:
Transmit Carriage Return Code (ODH).
LF:
Transmit Line Field (OAH)
Response Format
When the VisuaLink 128/384 is provisioned and controlled with a console, VisuaLink 128/384 always sends a 
response. Responses are normal response and error response.  When sending a command from a console, 
please transmit the next command after checking a response.  A response is transmitted in the following 
format.
Normal Ending
Parameter:   If a command is inquiring a provisioned value, a response parameter is returned. If there is no. 
parameter, it is omitted. However, if parameters are more than one, more than one space is 
transmitted between parameters.
Space:
More than one space is transmitted between a command and a parameter.
CR:
Transmit Carriage Rerun Code (ODH).
LF:
Transmit Line Field (OAH)
Error Ending
ERRxx: Three-character 
ERR and a 2-digit error number are transmitted indicating a failure.
CR:
Transmit Carriage Return Code (ODH). 
LF:
Transmit Line Field (OAH)
Report Format
Command: Transmit 4-character reports Command (only upper case can be used)
Space:
More than one space is transmitted between a command and a parameter
Parameter: If a command requires a parameter, a parameter is assigned. (Only upper case can be used)  
However, if parameters are more than one, more than one space is transmitted between parameters.
CR:
Transmit Carriage Return Code (ODH).
LF:
Transmit Line Field (OAH)
Command Name
Space
Parameter
CR+LF
Response Parameter (when required)
OK
CR+LF
ERRxx
CR+LF
Command Name
Space
Parameter
CR+LF