CX-Process Tool and Monitor
Connections to PLC
Note: The CX-Process functions that can be used depend on the version. For details, refer to the operation manuals (Cat. No.: W372-E1-
@ and
W373-E1-
@).
Note: 1. When using Windows Me, the CPU must be a Pentium 150 MHz or higher.
2. Peripheral Bus cannot be used when FinsGateway V3 is used.
Connections to PLC
The following 4 methods can be used to connect to a PLC.
Note: 1. The Windows 2000 and XP operating systems are supported. (Windows 95, 98, and Me are not supported.)
2. When CX-Server is used for communications, CX-Programmer can be simultaneously connected via the same COM port.
3. The Windows 95 operating system cannot be used.
Item
Specifications
Offline functions
ITEM data settings for function blocks
• Software connections for analog signals
• Displaying and printing text strings (annotation) 
pasted on function block diagrams and ladder 
diagrams.
• Instructions for step ladder blocks and commands for 
sequence table blocks
• Tag settings for CX-Process Monitor
• Engineering unit display setting
• Segment Program parameter setting
Construction of user screens
Online functions
• Transfer of function block data (Downloading/Upload-
ing for Loop Control Boards/Units.)
• Starting/stopping all function blocks (LCU/LCB)
• Monitoring system operation: Monitoring and 
controlling the System Common block (including 
LCB/LCU load rates)
• Validating LCB/LCU operation: Checking function 
block connections (including starting and starting 
individual function blocks), validating ladder 
diagrams and sequence tables, and monitoring 
ITEMs
• Tuning PID constants and other parameters 
(fine tuning and autotuning)
• Initialization of Loop Control Unit memory (RAM)
• External backup specifications
User screens
• Overview screen
• Control screen
• Tuning screen
• Trend screen
• Graphic screen
• Operating guide message screen
System screens
• Alarm history screen
• System monitor screen
• Operation log screen
Communications network
Communication driver
FinsGateway V3
FinsGateway Version 
2003 (See note 1.)
CX-Server V2.2
Host Link
Connection via PLC's peripheral port or 
RS-232C port
Supported. (Serial Unit version is used.)
Supported.
(See note 2.)
Peripheral Bus
Not supported.
Supported. 
Supported.
(See note 2.)
Controller Link
Connection to PLC with Controller Link Unit 
via Controller Link Support Board (PCI 
board).
Supported. (See note 3.)
(CLK (PCI) version is used.)
Supported.
Connection to PLC with Controller Link Unit 
via Controller Link Support Board (ISA 
board).
Supported. (CLK (ISA) version is used.)
Supported. 
Ethernet
Connection to PLC with Ethernet Unit via 
Ethernet Board.
Supported. (Ethernet version is used.)
Supported.