Nortel Networks NN44200-300 Benutzerhandbuch

Seite von 64
50
Chapter 5 Installing the server and connecting the peripheral devices
2
Locate the MAC address label on the back of the chassis that
identifies the ELAN controller MAC address.
3
Record the MAC address on the Configuration Wizard worksheet
that is provided in the Installation and Configuration Task List
(NN44200-306).
You need the MAC address to identify the ELAN when running the
Configuration Wizard to configure the CallPilot server.
4
Connect an RJ-45 network cable from the ELAN hub or switch to the
ELAN connector on the server.
Note: The ELAN hub or switch is optional if you use a cross-over
network cable to make a direct point-to-point connection from the
server to the switch. However, if you choose to establish a direct
point-to-point ELAN connection, no other device can connect
to the ELAN.
5
At the switch, connect the ELAN network cable to an MAU (Ethernet)
transceiver for a Meridian 1, or to the RJ45 ELAN connector for a
CS1000. Then complete the connection from the transceiver to the
switch.
DANGER
MAU model NTRH9069 is not suitable for installation in
ducts, plenums, or other spaces used for environmental
air. Do not install it above a false ceiling or below a raised
floor, unless it can be confirmed that these spaces are not
used to convey environmental air.
—End—
What is next?
the server will
THEN
be connected to the Nortel server
subnet
continue with
not be connected to a Nortel server
subnet
continue with installing the software
feature dongle. See
Nortel CallPilot
1002rp Server Hardware Installation
NN44200-300
01.01
Standard
5.0
23 February 2007
Copyright © 2007, Nortel Networks
Nortel Networks Confidential
.