Automatic Clock Adjustment Error Processing
Section 5-4
Note
For details on other error log information, refer to the Operation Manual, Con-
struction of Networks: SECTION 8 Troubleshooting
.
5-4-3
Error Log Error Codes for the Automatic Clock Adjustment 
Function 
When an error occurs while the Ethernet Unit is operating, the error code,
detailed error code, and time the error occurred are saved in the error log.
The following table provides a list of the error codes.
The error log can be read by sending FINS commands to the Ethernet Unit or
by using the mail receive function and specifying the ErrorLogRead com-
mand.
Error 
code
Meaning
Detailed error code
Correction
EEPROM
1st byte
2nd byte
021A
Logic error 
in setting 
table
00
01: Data link 
table
02: Network 
parameters
03: Routing 
tables
04: Setup
05: CPU Bus 
Unit Words 
(CIO/DM)
Recreate the data 
specified by the 
2nd byte of the 
detailed error 
code.
Saved
03C1
Server set-
ting error
00: DNS
01: SMTP
02: POP3
03: SNTP
01: IP address
02: Host name
03: Port number
04: Other 
parameters
Set the server 
settings correctly 
based on the 
information in the 
detailed error 
code.
---
03C4
Server 
connection 
error
00: DNS
01: SMTP
02: POP3
03: SNTP
01: Specified 
host does not 
exist
02: No service 
at specified host
03: Timeout
04: Closed uni-
laterally by host
05: Cannot con-
nect because 
account infor-
mation does not 
match
06: Host name 
resolution error
07: Transmis-
sion error
08: Reception 
error
09: Other error
Take either of the 
following mea-
sures.
• Correct the set-
tings for each 
server.
• Inspect the com-
munications 
path (Ethernet 
Unit, cable con-
nections, hub, 
router, server), 
and correct the 
situation that is 
causing the 
error.
---