34 Chapter 4 Installing the R2MFC MBM
NN40010-300
e Wait until the Status changes to Complete! It is safe to turn off the system.
f
Click Done.
g Exit the Unified Manager.
2 Attach one end of the grounding strap to your wrist and the other end to a grounded metal
surface.
3 Ensure the cables connected to the front of the BCM and the expansion unit are clearly marked
as to how they are connected.
4 Disconnect the BCM and expansion unit power cords from the AC outlet.
5 Remove the cables from all the R2MFC MBMs and the media services card (MSC) on the
BCM base function tray and the expansion unit (if attached).
Installing an R2MFC MBM
Follow the procedures in this section to install an R2MFC MBM in a BCM platform base chassis
or expansion unit.
or expansion unit.
Installing an R2MFC MBM in the BCM platform base chassis
Perform the following steps to install an R2MFC MBM in the BCM platform base chassis:
1 Ensure that both the faceplate and underside DIP switches on the R2MFC MBM are set
correctly. For information on how to set the faceplate switches, refer to
For information about how to set the underside switches, refer to the
Installation and Maintenance guide for the host BCM.
2 Select an open media bay.
3 With the face of the R2MFC MBM facing toward you, insert the R2MFC MBM into the open
bay.
4 Push the R2MFC MBM completely into the unit. You will hear a click when the module is
firmly seated in the media bay.
Caution: Only install the R2MFC MBM when the system is powered down. See