Fuji Bikes UG230 Series Benutzerhandbuch

Seite von 124
7-2
 1. 
Error 
Messages
Solution
1.
Confirm link unit settings.  (After making settings, cut power to the PLC.)
2.
Go to the editor and confirm the settings in the [Comm. Parameter] dialog in the [System Setting] 
menu.
3.
If errors only occur from time to time, it is possible that there is a noise-based communication error.
* If you still cannot solve the error even after following the suggestions above, contact your local 
distributor.
Error Messages for Network Communication
• Ethernet
Error Message
Contents
Solution
Error code received
The PLC sent an error code (NAK).
Examine the PLC error code and solve the 
problem.
Break
The PLC’s SD (TXD) remains at the low level.
Examine the connection between the PLC’s SD 
(TXD) and the UG series RD (RXD).
Invalid memory
(applicable to Mitsubishi 
CPU)
You specified an address that exceeds the 
memory range of the PLC that you are linked to.
Check the type and range of memory that you 
set.
Invalid CPU model
(applicable to Mitsubishi 
CPU)
The PLC currently being supported does not 
have a corresponding CPU.
Confirm whether or not the CPU that you are 
using can be used with the UG series.
Format
The code of the received data is invalid.
Check 1, 2, 3 described below.
Compare
(applicable to HIDIC S10)
Transmission data and received data are 
different.
Check 1, 2, 3 described below.
NAK
(applicable to 
Allen-Bradley PLC)
A NAK code is received.
Check 1, 2, 3 described below.
TNS discrepant
(applicable to 
Allen-Bradley PLC)
Transmitted TNS data and received TNS data 
are not in agreement.
Check 1, 2, 3 described below.
Communication Error
An unclear communication error is detected.
Check 1, 2, 3 described below.
Count error
(applicable to Mitsubishi 
CPU and Q link unit)
The expected data amount is different from the 
count value.
Check 1, 2, 3 described below.
Command error
(applicable to Mitsubishi 
CPU and Q link unit)
The response code differs from the expected 
code.
Check 1, 2, 3 described below.
Invalid cassette
(applicable to Mitsubishi 
ACPU)
This cassette is not included in the memory 
cassettes currently being supported.
Contact your local distributor.
Password error
(applicable to Mitsubishi 
QCPU)
The password is incorrect.
Contact your local distributor.
Error Message
Contents
Solution
Ethernet Error: XXXX
The Ethernet status is saved at system memory 
address $s518 and a code other than “0” 
(normal) is received.
XXXX: Error No.
For the contents and solution to each error 
number, refer to Appendix 5 of the User's 
Manual <Function> (FEH376) separately 
provided.