Fuji Bikes UG230H-SS4x Benutzerhandbuch

Seite von 124
7
2. Troubleshooting
7-5
Error Co
2.
Troubleshooting
In the Event of an Error
Perform the steps below:
1.
If the current error matches a symptom in the following table, correct it by following the instructions 
provided.
2.
If the error does not match the symptoms in the table, contact your local distributor.
Please provide the distributor with the information on the POD model, serial number, symptom of 
the error, error message (if shown), etc.
Probable Symptoms
Symptom
Cause
Solution
POD is connected to the 
PLC; however, 
communication fails. 
“Communication Error: 
Time-Out” appears on the 
screen. 
Probable causes are:
Solutions are:
1) Cables are not connected correctly or any 
cable is disconnected.
1) Check the cable connection.
2) PLC parameter settings are not correct or 
disagree with the POD settings.
2) Recheck the PLC parameter settings.
3) The POD is faulty.
3) Perform a self-loop test on the “I/O Test” 
screen (page 6-7). 
If the test is not successful, please return 
the POD to your local distributor 
immediately.
Communications have been 
successful.  However, 
opening a certain page 
always causes a 
“Communication Error: Error 
code received” error. 
The error code denotes a PLC error (NAK).
1) When the error code appears only on a 
certain screen, a memory address that 
does not exist on the PLC may be set on 
the POD screen.
1) Check if any address outside the allowable 
range for PLC memory is set on the screen.
2) When the error code appears at power-on, 
a memory address that does not exist on 
the PLC may be set for communication 
parameters, buffering area, initial macro, 
etc.
2) Check if any address outside the allowable 
range for PLC memory is set for 
communication parameters, buffering area, 
initial macro, etc.
Communications have been 
successful.  However, 
“Communication Error: 
Parity” or “Communication 
Error: Framing” suddenly 
occurs. 
Noise may cause the error.
Check if appropriate measures are taken 
against noise.
Example:
Check if communication and power cables are 
bundled together.
Try to attach a ferrite core to the 
communication cable.
Try to attach a noise filter to the power supply, 
etc.