Gateway E-9525R Benutzerhandbuch

Seite von 130
Replacing the RPS power distribution module
www.gateway.com
53
Replacing the RPS power distribution module
To replace the RPS power distribution module:
 
1
Follow the instructions in 
. Make sure that you turn off the server, then unplug the power 
cord(s) and all other cables connected to the server.
2
Follow the instructions in 
.
3
Remove the power supply modules by following the instructions in 
.
4
Disconnect the main power, CPU power, backplane power, I
2
C power, and 
midplane power cables. See 
 for the location of 
the connectors on the system board.
5
Push down the release bar (1). When the RPS power distribution module 
lifts (automatically), pull it away from the power supply cage (2) and 
remove it from the chassis.
Important
Make sure that the RPS power
distribution module is connected to the
power supply connector(s) on the power
supply(ies).
6
Align the new RPS power distribution module with the power supply cage 
(1), then push it down (2) onto the release bar. Make sure that the 
connectors on the back of the RPS power distribution module fit into the 
connectors on the power supply(ies).
7
Reconnect the power cables. See 
 for the 
location of the connectors on the system board.
8
Reinstall the power supply modules by following the instructions in 
.
9
Follow the instructions in