Gateway E-9525R Benutzerhandbuch

Seite von 130
Troubleshooting
www.gateway.com
81
LED information
See the following table for a description of this server’s LEDs and the information 
they provide:
9
The ROM checksum value does not match 
the value encoded in the BIOS.
Same as for 4 beeps.
10
The shutdown register for CMOS RAM 
failed.
Same as for 4 beeps.
11
The cache memory test failed.
Same as for 4 beeps.
Beeps
Description
Troubleshooting steps
LED Name
Function
Location
Color
Description
ID
Aid in server 
identification
Control panel 
and back of 
system board
Yellow 
(front)
Blue (back)
On - Server identification 
enabled
System Fault
Visible fault 
warning
Control panel
Red
Off - System normal
Blinking - Non-critical 
system fault
On - Critical system fault 
(system needs to be shut 
down and serviced)
Hard drive 
tray LEDs
Indicate drive 
status and 
activity
On each hard 
drive tray
Blue or red
Blue (On) - Hard drive 
present
Blue (Blinking) - Hard drive 
activity
Red (On) - Hard drive fault
Red (Blinking) - Hard drive 
rebuilding
Off - No hard drive access