8900NET  Instruction Manual
Enabling Alarms and Fan Speed Control Option
 
 
 
Enabling Alarms and Fan Speed Control Option
 
The 8900NET module has two eight-position DIP switches (S1 and S2) that 
enable or disable the fault reporting functions and the variable fan speed 
option (see 
). Enabled fault alarms drive on-board LEDs and can 
also be sent to SNMP monitoring stations when the SNMP network and 
Agent software has been installed and configured (see 
 
 
 
Figure 11.  Alarm Reporting DIP switches
 
Disabling (or filtering) specific fault alarms can be useful in isolating prob-
lems in the frame. Refer to 
 for the possible settings. A settings table 
is also silk-screened on the module.
 
Table 2.  Configuration DIP Switch Settings
 
S1 Segment
Left Position (open)
Right Position (closed)
 
1
PS1 Fault Reporting Enabled
PS1 Fault Reporting Disabled
2
PS2 Fault Reporting Enabled
PS2 Fault Reporting Disabled
3
(Not used) Over Temp reporting is always enabled locally and through SNMP
4
Fan Fault Reporting Enabled
Fan Fault Reporting Disabled
5
Module Fault Reporting Enabled
Module Fault Reporting Disabled
6
Frame Bus Error Reporting Enabled 
Frame Bus Error Reporting Disabled 
7
Fan Speed Controlled by Temperature
Fan Speed Fixed at Maximum
8
Network Module Control Enabled (remote 
control via GUI is enabled)
Network Module GUI is placed in read only 
mode
 
S2 Segment
Left Position (open)
Right Position (closed)
 
1
Status Enabled (enabled alarms are 
reported over SNMP)
SNMP Reporting is disabled except for 
Over Temp alarm
2
IP Address (not currently supported)
3
Frame Control Enabled (remote control via 
GUI is enabled)
GUI for the frame and all modules within is 
placed in read only mode
4 – 8
(Currently Not Used)
12345678
12345678
S2
S1
Power Supply #1
Power Supply #2
Temperature
Fan
Module
Frame Bus
Fan Speed
NM Control
Status
8900NET
IP Address
Frame Control
Remote
Override
LED