Ethernet Communication Module DVPEN01-SL
 
DVP-PLC Application Manual 
 
10
Storing the data to be transmitted to the remote MPU. 
C R # 4 9   ~   6 8 :  
Data Receiving Buffer 
Explanations: 
Storing the data received from the remote MPU. 
C R # 8 1 :
 Read Address for Data Exchange 
Explanations: 
Setting up manually the Modbus address of the register for Slave data exchange. Only register 
address is allowed (e.g. D0 = H’1000). 
C R # 8 2 :  
Read Length for Data Exchange 
Explanations: 
The number of receiving registers (K1 ~ K128) in data exchange. 
C R # 8 3 :  
Read Length for Data Exchange 
Explanations: 
Setting up the Modbus address of the register for Master data exchange. 
C R # 8 4 :  
Written-in Address for Data Exchange 
Explanations: 
Setting up manually the Modbus address of the register for Slave data exchange. 
C R # 8 5 :
 Written-in Address for Data Exchange 
Explanations: 
The number of transmission registers (K1 ~ K128) in data exchange. 
C R # 8 6 :  
Transmission Address for Data Exchange 
Explanations: 
1. Setting up the Modbus address of the register for Master data exchange. 
2. Example: Write H’1000 (D0) into CR#81, K1 into CR#82, and H’1064 (D100) into CR#83. If 
the data exchange is successful, the value in D0 of the Slave will be written into D100 of the 
MPU. Or write H’1002 (D2) into CR#84, K4 into CR#85, and H’1008 (D8) into CR#86. If the 
data exchange is successful, the value in D8 ~ D11 of the Master will be written into D2 ~ D5 
of the Slave. Both sending and receiving can be executed at the same time. When the values 
in CR#82 and #85 are both “0”, DVPEN01-SL will use the default registers (CR#29 ~ CR#68) 
and number of registers (K20). 
„
  Network Settings 
C R # 6 9 :
 DHCP/Static IP 
Explanations: 
You can select either DHCP or Static IP. When the CR value is set as “0” Æ Static IP; When the 
CR value is set as “1” Æ DHCP (dynamic IP).