 Chapter 7 Servo Parameters|ASDA-AB Series 
Revision January 2009 
 
7-27
 
Group 1: P1-xx  Basic Parameters 
P1 - 00 
  PTT 
External Pulse Input Type 
Communication Addr.: 0100H
Default: 2 
Related Section: 
Applicable Control Mode: Pt 
Section 6.2.1 
Unit: N/A 
 
Range: 0 ~ 132 
 
Settings:  
not used
A
B
C
 
•  Value A: Pulse type 
  A=0: AB phase pulse (4x) 
  A=1: CW + CCW pulse 
  A=2: Pulse + Direction
•  Value B: Input pulse filter  
 B=0: 
500Kpps 
 B=1: 
200Kpps 
 B=2: 
150Kpps 
 B=3: 
80Kpps 
This setting is used to suppress or reduce the chatter 
caused by the noise, etc. However, if the instant input 
pulse filter frequency is over high, the frequency that 
exceeds the setting value will be regarded as noise and 
filtered. 
•  Value C: Logic type 
0=Positive Logic 
1=Negative Logic 
Pulse Type 
Forward 
Reverse 
Forward 
Reverse 
AB phase pulse 
 
 
CW + CCW pulse 
 
 
Pulse + Direction 
 
 
 
Input pulse interface 
Max. input pulse frequency 
Line driver 
500Kpps 
Open collector 
200Kpps 
• Other setting: Reversed