Delta Electronics ASDA-AB Benutzerhandbuch

Seite von 357
Chapter 9  Maintenance and Inspection|ASDA-AB Series
 
9-2  
 
Revision January 2009
 
Item 
Content 
Inspection during 
operation 
(Control power is 
applied)) 
z
  Ensure that the cables are not damaged, stressed excessively or loaded heavily. 
When the motor is running, pay close attention on the connection of the cables 
and notice that if they are damaged, frayed or over extended. 
z
  Check for abnormal vibrations and sounds during operation. If the servo motor is 
vibrating or there are unusual noises while the motor is running, please contact 
the dealer or manufacturer for assistance. 
z
  Ensure that all user-defined parameters are set correctly. Since the 
characteristics of various machinery are different, in order to avoid accident or 
cause damage, do not adjust the parameter abnormally and ensure the 
parameter setting is not an excessive value. 
z
  Ensure to reset some parameters when the servo drive is off (Please refer to 
Chapter 7). Otherwise, it may result in malfunction. 
z
  If there is no contact sound or there be any unusual noises when the relay of the 
servo drive is operating, please contact your distributor for assistance or contact 
with Delta. 
z
  Check for abnormal conditions of the power indicators and LED display. If there is 
any abnormal condition of the power indicators and LED display, please contact 
your distributor for assistance or contact with Delta. 
 
9.2 Maintenance 
„
 
Use and store the product in a proper and normal environment. 
„
 
Periodically clean the surface and panel of servo drive and motor. 
„
 
Make sure the conductors or insulators are corroded and/or damaged. 
„
 
Do not disassemble or damage any mechanical part when performing maintenance. 
„
 
Clean off any dust and dirt with a vacuum cleaner. Place special emphasis on cleaning the ventilation 
ports and PCBs. Always keep these areas clean, as accumulation of dust and dirt can cause unforeseen 
failures. 
 
9.3  Life of Replacement Components 
„
 
Smooth capacitor 
The characteristics of smooth capacitor would be deteriorated by ripple current affection. The life of 
smooth capacitor varies according to ambient temperature and operating conditions. The common 
guaranteed life of smooth capacitor is ten years when it is properly used in normal air-conditioned 
environment. 
„
 
Relay 
The contacts will wear and result in malfunction due to switching current. The life of relay varies 
according to power supply capacity. Therefore, the common guaranteed life of relay is cumulative 
100,000 times of power on and power off.