Delta Electronics ASDA-AB Benutzerhandbuch

Seite von 357
Chapter 12  Application Examples |ASDA-AB Series 
Revision January 2009 
 
 
12-25 
12.7  Internal Auto Running Mode 
„
 
Relevant Parameters Description 
Parameter 
Communication 
Address 
Parameter Description 
P1-01 
0101H 
Control Mode and Output Direction 
001: Forward torque in Pr mode 
101: Reverse torque in Pr mode 
P1-33 
0121H 
Position Control Mode (Pr) 
5: Continuous auto-running position command (Absolute) 
6: Continuous auto position command (Incremental) 
P1-34 0122H 
Acceleration 
Time 
1st to 3rd step Acceleration time (When parameter P1-36 is set to 0, 
accel / decel function is disabled, i.e. P1-34, P1-35 is disabled) 
P1-35 0123H 
Deceleration 
Time 
1st to 3rd step Deceleration time (When parameter P1-36 is set to 0, 
accel / decel function is disabled, i.e. P1-34, P1-35 is disabled) 
P1-36 
0124H 
Accel /Decel S-curve 
When parameter P1-36 is set to 0, accel / decel function is disabled, 
i.e. P1-34, P1-35 is disabled. 
P1-44 
012CH 
Electronic Gear Ratio (1st Numerator) (N1) 
If the electronic gear deceleration ratio is 1/75, set numerator to 75 
P1-45 
012DH 
Electronic Gear Ratio (Denominator) 
P1-47 012FH 
Homing 
Mode 
202: When (MD1, MD0)=(OFF, ON), Forward Homing 
203: When (MD1, MD0)=(OFF, ON), Reverse Homing 
P1-50 
0132H 
Homing Offset Rotation Number 
P1-51 
0133H 
Homing Offset Pulse Number 
Total homing offset pulse number =P1-50 x 10000 + P1-51 
P2-44 
022CH 
Digital Output Mode Setting 
0: General output mode 
1: Combination output mode 
P2-45 
022DH 
Combination Output Signal Delay Time [UNIT: 4msec] 
Output signal will hold delay time when position command is 
completed. 
P2-51 
0233H 
Internal Servo ON setting