Delta Electronics LCP-155A4HSRBx Benutzerhandbuch

Seite von 12
 
 
DELTA ELECTRONICS, INC.
 
8 2007/11/6
Rev. 0D
www.deltaww.com
 
SFP timing parameters for SFP management 
Parameter Symbol 
Min.
Max.
Unit
Unit 
Conditions 
TX_DISABLE Assert 
time 
t_off  
10 
µsec
Time from rising edge of TX_DISABLE to 
when the optical output falls below 10% of 
nominal 
TX_DISABLE 
Negate time 
t_on  
msec
Time from falling edge of TX_DISABLE to 
when the modulated optical output rises 
above 90% of nominal 
Time to initialize, 
including reset of 
TX_FAULT 
t_init  
300
msec
From power on or negation of TX_Fault using 
TX Disable. 
TX Fault Assert 
Time 
t_fault 
 
 100
µsec Time from fault to TX fault on. 
TX_DISABLE to 
reset 
t_rest 10  
µsec
Time TX Disable must be held high to reset 
TX_Fault 
LOS Assert Time 
t_loss_on 
 
100
µsec Time from LOS state to Rx LOS assert 
LOS Deassert Time 
t_loss_off 
 
100
µsec Time from non-LOS state to Rx LOS deassert
Serial ID Clock Rate  f_serial_clock 
 
100