B–Flash Update
QLogic Adapter Flash Update—Windows Server
NE0154601-00  B
B-7
Here is an example of a Windows Server nxflash --info output for local 
area connection 0:
C:\Users\Administrator\Desktop\4.0.223\utils>nxflash.exe -i 
“Local Area Connection 0” --info
NETXEN Port is Port 0
Verifying flash...Done.
Board Type
: 0x24 (Quad Gig LP)
Board Chip Rev
: B1
Serial Id
: QG87BK0092
Efuse ID
: 0x4e36343633340f08
Firmware version (on Flash) : 4.0.228
Active Firmware version
: 4.0.229
Firmware in
: CUT-THRU mode
Driver version
: 4.0.229
BIOS version
: 2.0.0
MAC Addr 0
: 00:0E:1E:00:79:DC
MAC Addr 1
: 00:0E:1E:00:79:DD
MAC Addr 2
: 00:0E:1E:00:79:DE
MAC Addr 3
: 00:0E:1E:00:79:DF
Subsystem ID
: 0x01244040
PHY Type
: UNKNOWN PHY
PXE Status
: Disabled
Updating the Flash on Multiple Standalone QLogic Adapters
The Flash can be updated on multiple QLogic adapters on the same host using 
one of the following procedures.
To perform updates from the same directory tree, type the following 
commands sequentially after the Flash update has completed. In these 
commands, n represents two different port numbers, for example, “Local 
Area Connection 4” and “Local Area Connection 5” (the 
quotation marks are required). 
nxflash.exe -i “Local Area Connection n” --all (first 
QLogic adapter)
nxflash.exe -i “Local Area Connection n” --all (second 
QLogic adapter)