Zhone Technologies 600 Benutzerhandbuch

Seite von 240
4-4 
Server Cards
Model No.
Running Head
ACS-ATM Card User Screens and Settings
ATM Card
Table 4-1. ACS-ATM Card Main Screen Actions (DS3)
Table 4-2.  ACS-ATM Card Main Screen Options and Defaults (DS3)
STATE (DS3)
The State setting determines whether the port is active or inactive. Set State to stdby (standby) 
for ports not being used or not yet configured. Set it to actv (active) for ports that are ready 
for use for ATM traffic.
FORMAT (DS3)
The Format setting indicates the variety of DS3 C-bit application used by this port. The 
choices are Cbit and M23. This parameter is defined in RFC 1407.
CELL FRM (DS3)
The Cell Framing setting indicates the way ATM cells are constructed from the DS3 bitstream. 
The two options are plcp (cells are constructed from the PLCP mapping bits) and hcs (the cells 
are constructed from the HEC in the cell header).
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Redraws the screen.
uNi
Brings up the User Network Interface (UNI) Configuration Screen.
Vbr
Brings up the Variable Bit Rate (VBR) Configuration Screen.
Cbr
Brings up the Constant Bit Rate (CBR) Configuration Screen.
Perf
Brings up the DS3 Port Performance Data Screen.
Main
Returns to the System Main Screen. If changes are made to settings and not 
saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
STATE
stdby     actv
stdby
FORMAT
Cbit M23
Cbit
CELL FRM
plcp  hcs
plcp
LB CFG
off local line payld cell
off
LB GEN
off  line  paylod  reset
off
LB DET
off on w/to
off
TX CLKSRC
line  plcp
line
TX-RX SCRAM
yes  no
yes
TX-LBO
off on
off
IDLE-UASN
uasn idle
uasn