7-16 
Server Cards
Model No.
Running Head
Inverse Multiplexer (IMUX) Card Settings
IMUX Card
TXDISC TIMER
The Timer (bothway) Disconnect setting defines the duration of time necessary for sending 
the disconnect indication prior to disconnecting the call. The values (in milliseconds) are 
100020003000 and 4000. This timer is used for mode1 calls.
TCID TIMER
The Timer Channel Identifier setting defines the duration of time spent by the network looking 
for secondary B channel allocation information before disconnecting the call. The values (in 
milliseconds) are 100020003000 and 4000. This timer is used for mode2 and mode3 calls 
(when available).
TANULL TIMER
The Timer (answer) Null State setting defines the duration of time spent by the called user 
looking for bonding information before disconnecting the call. The values (in milliseconds) 
are 500025007500 and 10000. This timer is used for mode0 and mode1 calls.
TXDEQ TIMER
The Timer (bothway) Delay Equalization setting defines the duration of time given the called 
user to complete equalization of the call. The values (in milliseconds) are 2000010000
30000 and 50000. This timer is used for mode1 calls.
TXFA TIMER
The Timer (bothway) Frame Alignment setting defines the duration of time (per channel) for 
the called user needs to find frame alignment. The values (in milliseconds) are 2000010000
30000 and 40000. This timer is used for mode1 calls.
Table 7-10. The IMUX Call Screen Actions
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically 
updated (i.e. performance and test data).
Main
Returns to the HSU call profile screen. If changes are made to settings and 
not saved, you will be prompted to save or lose changes.