5. Connection Procedure to the user system 
 
Connect the emulation probe to the  connector  on  the  upper panel of the M37549T-RLSS. Connect the M37549T-RLSS to the 42-pin 
SDIP socket on the user system. Table 2 shows pin allocation of the M37549T-RLSS, and Figure 2 shows connector dimensions. 
 
Table 2    CN1 connector pin allocation 
Pin No 
Signal 
Pin No 
Signal 
1 N.C 
42 
N.C 
2 N.C 
41 
N.C 
3 N.C 
40 
P13/AN3/KEY3 
4 P14/AN4/KEY4 
39 
P12/AN2/CMP2 
5 P15/AN5/KEY5 
38 
P11/AN1/CMP1 
6 RESET 
37 
P10/AN0/CMP0 
7 P16/AN6/KEY6 
36 
P31 
8 P17/AN7/KEY7 
35 
P30 
9 N.C 
34 
Reserved 
10 N.C 
33 Reserved 
11 N.C 
32 Reserved 
12 P20/Xout/Xcout 
31 Reserved 
13 Vss 
30 P07(LED7)/Srdy 
14 P21/Xin/Xcin 29 P06(LED6)/Sclk 
15 Vcc 
28 P05(LED5)/TxD 
16 CNVss 
27 P04(LED4)/RxD 
17 P00(LED0)/INT0 
26 P03(LED3)/CAP0 
18 P01(LED1)/INT1 
25 P02(LED2) 
19 N.C 
24 N.C 
20 N.C 
23 N.C 
21 Vss 
22 N.C 
* Do not connect signal to Reserved parts. 
 
1
42
21
22
15. 24
1 . 778
 
 
Figure 2    CN connector dimensions