IBM DS4000 FC Benutzerhandbuch

Seite von 84
where
 
xxxx
 
is
 
the
 
adapter
 
address.
 
If
 
xxxx
 
is
 
omitted,
 
then
 
the
 
program
 
will
 
attempt
 
to
 
change
 
(on
 
all
 
of
 
the
 
adapters
 
in
 
the
 
host)
 
the
 
standard
 
NVRAM
 
defaults
 
in
 
the
 
adapter,
 
to
 
the
 
new
 
defaults
 
from
 
the
 
NVRAM
 
files.
 
 
8.
   
Press
 
″Enter.″
 
 
9.
   
The
 
flasutil
 
program
 
will
 
display
 
the
 
existing
 
version
 
of
 
the
 
NVRAM,
 
the
 
newer
 
NVRAM
 
version,
 
and
 
a
 
message
 
telling
 
you
 
if
 
the
 
update
 
was
 
successful
 
or
 
unsuccessful.
 
The
 
following
 
output
 
example
 
resembles
 
the
 
output
 
you
 
might
 
see
 
upon
 
execution
 
of
 
the
 
flasutil
 
/i
 
/u
 
xxxx
 
/n
 
NVRAMfile.DAT
 
command,
 
where,
 
for
 
this
 
example,
 
2300
 
is
 
substituted
 
for
 
xxxx
.
 
QLogic
 
NOVRAM
 
and
 
FLASH
 
Programming
 
Utility
 
Version
 
1.55
 
Copyright
 
(C)
 
QLogic
 
Corporation
 
1998-2005.
 
All
 
rights
 
reserved.
 
  
   
Programming
 
QLA2422
 
NOVRAM
 
at
 
Address
 
2300
 
   
NOVRAM
 
at
 
Address
 
2300
 
Loaded
 
Successfully
 
   
Updating
 
flash
 
at
 
I/O
 
Address
 
2300
 
   
Verifying
 
flash
 
at
 
I/O
 
Address
 
2300
 
   
Flash
 
at
 
I/O
 
Address
 
2300
 
Verified
 
Successfully
 
  
C:\
 
10.
   
To
 
update
 
the
 
FC
 
4Gbps
 
PCI-X
 
Adapter
 
BIOS
 
version
 
number,
 
type
 
vpd
 
/a
 
/u
 
and
 
press
 
″Enter.″
Note:
  
IBM
 
does
 
not
 
support
 
any
 
vpd
 
program
 
options,
 
other
 
than
 
/a
 
and
 
/u
.
 
The
 
following
 
output
 
example
 
resembles
 
the
 
output
 
you
 
might
 
see
 
upon
 
execution
 
of
 
the
 
vpd
 
/a
 
/u
 
command.
 
Processing
 
all
 
adapters...
 
   
2422
 
at
 
address
 
2300
  
[1077.2422.1077.0134.0]
 
   
Reading
 
vpd
 
from
 
nvram...
 
   
Reading
 
versions
 
from
 
flash...
 
   
Updating
 
vpd
 
in
 
nvram...
 
   
Verifying...
 
   
Verify
 
passed
 
   
2422
 
at
 
address
 
2400
  
[1077.2422.1077.0134.1]
 
   
Reading
 
vpd
 
from
 
nvram...
 
   
Reading
 
versions
 
from
 
flash...
 
   
Updating
 
vpd
 
in
 
nvram...
 
   
Verifying...
 
   
Verify
 
passed
 
  
C:\
 
Note:
  
This
 
example
 
shows
 
what
 
would
 
be
 
displayed
 
when
 
there
 
is
 
one
 
QLA2462
 
adapter
 
installed
 
in
 
the
 
server,
 
with
 
port
 
I/O
 
addresses
 
2300
 
and
 
2400.
 
11.
   
To
 
review
 
additional
 
command-line
 
options
 
that
 
you
 
can
 
use,
 
go
 
to
 
 
then,
 
continue
 
with
 
Step
 
 
12.
   
CD:
 
Remove
 
the
 
CD
 
from
 
the
 
CD-ROM
 
drive
 
and
 
restart
 
the
 
server.
 
Diskette:
 
Remove
 
the
 
diskette
 
from
 
the
 
diskette
 
drive
 
and
 
restart
 
the
 
server.
 
13.
   
Go
 
to
 
Command-line
 
options
 
This
 
section
 
describes
 
additional
 
command-line
 
options
 
that
 
you
 
can
 
use.
 
Complete
 
the
 
following
 
steps
 
to
 
review
 
these
 
command-line
 
options:
 
 
18
 
IBM
 
System
 
Storage
 
DS4000
 
FC
 
4Gbps
 
PCI-X
 
Single/Dual
 
Port
 
HBA:
 
Installation
 
and
 
User’s
 
Guide