GSMVLP5 GSM and  
ILP5 Ethernet 
Communications Modules
 
 
Installation and Setup Guide 
Installing Communication Modules 
!
 
RF Exposure 
WARNING: The antenna(s) used for this transmitter must be installed to provide a separation distance of 
at least 20 cm from all persons and must not be co-located or operating in conjunction with any other 
antenna(s) or transmitter.
 
Installing the GSMVLP5 in the LYNX Touch Series Control 
 
 
Ensure that SIM card and the connector board are securely installed in the GSMVLP5 before installing the 
module in the LYNX Touch.
 
 
1.  Install the provided FCC/IC label (P/N 800-08334) on the control’s case back (refer to Figure 1). 
5000-100-186-V0
FCC ID:  CFS-8DLL
YNXTOUCH1
IC: 573F-L
YNXTOUCH1
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES AND RSS 210 OF INDUSTRY
CANADA. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS
DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESIRED OPERATION.
800-08126   1/11    Rev A
LYNX TOUCH SERIES
COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION NO.: AC3AL05BL5000
RINGER EQUIVALENCE: 0.1B
IC MODEL: L
YNXTOUCH1
CONTAINS TRANSMITTER MODULE
  IC: 7830A-MC55I
FCC ID: QIPMC55I
800-08334   2/11    Rev A
FCC ID: CFS-8DLLYNXTOUCH1
IC: 573F-LYNXTOUCH1
LYNX TOUCH SERIES
IC MODEL: LYNXTOUCHG1
 
Figure 1. FCC/IC Label Location 
 
2.  Release the LYNX Touch front case from the back case by depressing the two locking tabs at the top of the 
unit with the blade of a medium size screwdriver (Refer to Figure 2). 
3.  Install the GSMVLP5 into the LYNX Touch control front case. Ensure that the connector board is properly 
seated into the receptacle on the control (Refer to Figure 2). 
4.  Secure the GSMVLP5 with the three provided screws (Refer to Figure 2). 
5.  Enable the GSMVLP5 device, configure alarm reporting and module supervision and register the device. 
Refer to the “Program the Radio” and “Diagnostics” sections in the LYNX Touch Series Installation and 
Setup Guide (P/N 800-06834 or higher). 
 
 