BBM Functional Description
A-4
AcceleRAID 352 Installation Guide
 
Status Indication 
Battery status can be checked, and the battery can be reconditioned, or 
charged using the Intelligent Battery Backup Unit dialog box in Global 
Array manager Client. This is accessed by selecting the Intelligent BBU 
option on the Administration menu. Please refer to the Global Array 
Manager Client Software Installation Guide and User Manual
.
Battery and Charge Circuit 
On-board Battery 
The on-board battery is rated at 4.1 V with a capacity of 900 mAH. The 
BBM has a DC-DC converter that converts 4.1 V to 3.3 V, which is the 
nominal voltage required for the cache. 
Battery Charger 
Battery charging is automatically handled by the BBM. No manual 
preconditioning needs to be performed by the user. If the battery capacity 
falls below a predetermined level (which is likely to happen after a power 
failure), the battery charger goes into a quick charge mode. The battery 
charger will operate in a temperature range from 0°C to +45°C.
Disposition of Failed Batteries
Currently, requirements for disposal or recycling of rechargeable Lithium- 
Ion batteries are under consideration by many agencies, both local and 
international. Lithium-Ion batteries should not be punctured or incinerated 
(the electrolyte can generate steam and cause the gas to explode). 
The battery on the BBM contains the following text: 
“Li-Ion Battery. Must be disposed of properly.”
Contact your local authorities to determine the appropriate method of 
disposal.