ADC HDSL4 Benutzerhandbuch

Seite von 79
LTPH-UM-1031-03, Issue 3
 
Provisioning
H4TU-C-319 List 1
September 12, 2003
 17
Configuring the System
The Config menu (
allows you to make the following types of system configuration changes:
Standard options (
)
ADC options (
BERT Generator (
Date and time (see 
Master clear (see 
Reset to factory default configuration (
Figure 6.
Config Menu
Making Changes to Standard and ADC Options
 show the Standard and ADC configuration options. Standard options are 
supported by HDSL4 units when connected to units from other vendors. ADC options are an extended set of 
options available only when using ADC units exclusively. For a description of each option and a list of possible 
option settings, refer to 
. To make changes to these options:
1
Press 
 to select the Config menu.
2
Use the 
 and 
 arrow keys to select Standard Options or ADC Options, then press 
.
3
Use the arrow keys to select an option.
4
Press the 
 to cycle through the available settings for that option. 
5
Press 
 to activate your choice.
The message 
May need to change MUX option after changing this option
 
appears when changing the DS1 Line Coding (DS1) or H4TU-C Equalization (EQL) option in the 
Standard Options configuration screen. (This applies when the H4TU-C is used in a 
Wideband 3190 which contains a multiplexer.) 
Monitor  Performance  Event Log  
Config
  Inventory  Report  Rlogon         Help
                                +----------------------+
                                |
 Standard Options ->  
|
                                | ADC Options      ->  |
                                | BERT Generator   ->  |
                                | Date and Time    ->  |
                                | Master Clear         |
                                | Set Factory Defaults |
                                +----------------------+
 ID: xxxx--xxxx—-xxxx--xxxx   02/01/2002 12:30:01   H4TU-C        System: OK
___
C
ENTER
SPACEBAR
ENTER