Chapter 3
Device Configuration
16
Cajun M770 Manager User’s Guide
Viewing ATM Clock Synchronization Configuration
Some multimedia applications, such as voice, require that a single clock is 
propagated throughout the network. The clock source is usually a Public Telco 
switch connected to a local PBX through a telephony network. Using the Cajun 
M770 ATM Device, up to four external references can be configured, two from 
ATM ports and two from external E1/T1 sources. These are all directed to the 
M-SPS module which selects one of them to be the source input timing device. It 
uses the selected source to generate a 19.44MHz clock which is distributed to all 
modules. This is used by all ATM ports to synchronize Sonet frames.
The ATM Clock Synchronization dialog box provides information about the 
method currently configured for synchronizing the clocks in the Cajun M770 
Device. 
To view and edit clock synchronization parameters from Chassis View:
1
Click .
OR
Open the Configuration menu and select ATM Clock Sync. The ATM Clock 
Synchronization dialog box appears.
Figure 3.6
Clock Synchronization Dialog Box
The ATM Clock Synchronization dialog box shows the module type, status, and 
current source of clock synchronization. It also provides a table of clock 
synchronization parameters for all the clock sources, and allows you to edit their 
configurations.
To edit the configuration of a clock synchronization source:
1
Select one of the sources from the table.
2
Modify the parameters in the Row Configuration area of the dialog box.
3