Panasonic M1111TY0 -FJ Benutzerhandbuch
137
Menu
Menu
Sub menu
Parameter 1
Parameter 2
Parameter 3
Parameter 4
Use [F1] to select.
Use [F2] to select. Use [F3] to select. Use [F4] to select. Use [F5] to select.
System /Locked
(When locked)
(Message)
Display only
System menu is locked
System /Unlocked
(When unlocked)
Format
Parameter
Format (
)
Hi Resolution
16:9 Squeeze
Setting range
1080/59.94i,
1080/50i,
1080/24PsF,
1080/23.98PsF,
720/59.94p,
720/50p,
480/59.94i,
576/50i
1080/50i,
1080/24PsF,
1080/23.98PsF,
720/59.94p,
720/50p,
480/59.94i,
576/50i
On, Off
(Selection
enabled when SD
format is used)
(Selection
enabled when SD
format is used)
On, Off
(Selection
enabled when SD
format is used)
(Selection
enabled when SD
format is used)
Default value
1080/59.94i
Off
Off
Output Phase
Parameter
System
H-Phase
V-Phase
Setting range
0H, 1H
The setting range
differs from one
format to another.
differs from one
format to another.
1080/59.94i:
1100 to 1099
1080/50i:
1320 to 1319
1080/24PsF:
1375 to 1374
1080/23.98PsF:
1375 to 1374
720/59.94p:
825 to 824
720/50p:
990 to 989
480/59.94i:
429 to 428
576/50i:
432 to 431
1100 to 1099
1080/50i:
1320 to 1319
1080/24PsF:
1375 to 1374
1080/23.98PsF:
1375 to 1374
720/59.94p:
825 to 824
720/50p:
990 to 989
480/59.94i:
429 to 428
576/50i:
432 to 431
100 to 100
Default value
0H
0
0
Reference
Parameter
Sync (
)
BB Setup
Gen Lock
Setting range
BB,
BB Advanced,
Tri-level sync,
Internal
BB Advanced,
Tri-level sync,
Internal
0IRE, 7.5IRE
Locked, UnLock
Default value
BB
7.5IRE
UnLock
Ancillary
Parameter
AUX
PGM
PVW
MV
Setting range
On, Off
On, Off
On, Off
PGM, PVW, Off
Default value
Off
Off
Off
Off
Alarm
Parameter
Power
Fan
Temperature
Display only
Alarm,
No Alarm
No Alarm
Alarm,
No Alarm
No Alarm
Alarm,
No Alarm
No Alarm
Initial
Parameter
Initial (
)
Fader Initial
Setting range
Mode A,
Mode B
Mode B
Execute
Default value
Mode A
5. Setting menu table