2-32
Reference Guide
                           Frame Relay Configuration
         LMI Type...                        ANSI (Annex D)
         T391 (Polling Interval in secs):   10
         N391 (Polls/Full Status Cycles):   6
         N392 (Error Threshold):            3
         N393 (Monitored Event Window):     4
         Tx Injection Management...         Standard
         Default CIR:                       64000
         Default Bc:                        64000
         Default Be:                        0
         Congestion Management Enabled:     Yes
Maximum Tx Frame Size:             1536
Enter Information supplied to you by your telephone company.
1.
Select LMI Type (Link Management Type) and press Return. From 
the pop-up menu, highlight either ANSI (Annex D), CCITT (Annex 
A), LMI, or None. The world-wide default is ANSI (Annex D). 
Press Return.
Note: If you select None as an LMI Type, the four LMI options 
listed below will remain hidden, and you will need to manually 
configure DLCIs. See 
 for instructions.
Specifying the Link Management Type is the first step in 
configuring Frame Relay.
If you select an LMI Type (Link Management Type) other than 
None, the T391 option specifies the number of seconds 
between the Status Enquiry messages. The default setting is 
10.
The N391 option specifies the frequency of full status polls, 
in increments of the basic (T391) polling cycle. The default 
setting is 6.