Nokia 7000 Series Benutzerhandbuch

Seite von 151
 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual
75
VPD-6830-XEQ
 Chapter 8: VPD-6830 Programmable Video DA Series
VPD-6830-XEQ
Configuration
1. Set the Input Coupling for either AC or DC coupling using jumpers 
J2
 and J3See Figure 8-7 on page 76 for jumper locations.
2. Set the Clamping mode on jumper J1 to either SoftHard or No 
Clamp
See Figure 8-7 on page 76 for jumper location.
3. Adjust the gain over a range of -3 dB to +3 dB using the R5 
multi-turn potentiometer in the base module. 
Turn the potentiometer clockwise to increase the gain. See 
Figure 8-8 on page 76.
4. Adjust the equalization using the R6 multi-turn potentiometer in the 
base module. 
Turn the potentiometer clockwise to obtain more equalization. See 
Figure 8-8 on page 76.
5. Make fine adjustments to the high-frequency response using the R21 
single-turn potentiometer in the base module. 
The high-frequency response is factory-set/calibrated. 
Readjustment is not recommended without precise test equipment. 
See Figure 8-8 on page 76.
6. Select the cable length range compensation with jumpers J1 and J2
located on the VPD-SBEQ submodule. See Figure 8-7 on page 76.
The R6 equalization potentiometer 
on the VEA-6840 (Figure 8-7) is 
used for continuous equalization 
adjustments from 0 to 1000 ft
 (300 m).