Nokia 7000 Series Benutzerhandbuch

Seite von 151
 Chapter 8: VPD-6830 Programmable Video DA Series
VPD-6830-DLY240
88
 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual
VPD-6830-DLY240
 
Configuration
The VPD-6830-DLY240 provides adjustable delay from 0 to 240 ns. The 
additional delay submodule is shown on the VEA-6840 base card in 
Figure 8-15 on page 91. 
To configure the VPD-6830-DLY240:
1. Set the Input Coupling for either AC or DC coupling using jumpers 
J1
 and J2. See Figure 8-15 on page 91 for jumper locations.
2. Set the clamping mode on jumper J3 to either SoftHard, or No 
Clamp
See Figure 8-15 on page 91 for jumper location.
3. Adjust the gain over a range of -3 dB to +3 dB using the R5 
multi-turn potentiometer in the base module. 
Turn the potentiometer clockwise to increase the gain. See 
Figure 8-16 on page 92.
4. Adjust the equalization using the R6 multi-turn potentiometer in the 
base module.
Turn the potentiometer clockwise to obtain more equalization. See 
Figure 8-16 on page 92.
5. Make fine adjustments to the high-frequency response using the R21 
single-turn potentiometer in the base module. 
The high-frequency response is factory-set/calibrated. 
Readjustment is not recommended without precise test equipment. 
See Figure 8-16 on page 92.
6. Position the delay submodule P2 jumpers horizontally across the 
jumper sockets, connecting pins 2 & 4, and pins 1 & 3. 
Connecting the jumpers horizontally puts them in Bypass mode. 
Connecting them vertically puts them in Use mode. See Figure 8-15 on page 91 for an illustration of this jumper set.
7. Position the delay submodule P3 jumpers either horizontally 
(Bypass mode) or vertically (Use mode) across the jumper sockets. 
Jumper P3 is a six-section, two-position jumper set. This jumper 
“selects” the desired amount of selectable delay. For each section, 
there are two jumper positions: horizontal and vertical. The 
horizontal position is Bypass mode, where a designated amount of 
delay can be bypassed. The vertical position is the Use position,