Error Detection and Reporting
 Chapter 1: AES-6880 AES/EBU Digital Audio Distribution Amplifier Module
Error Detection and Reporting
The AES-6880 DA constantly monitors the incoming AES data stream 
and reports the following error conditions via the LED indicators 
mounted near the card’s front edge. LED indicators and conditions are 
described in the following table: 
Condition
Indicator
Description Of Condition
All OK; 
No Errors
Green LED
No errors detected. 
No Lock
Red LED
Signal is not present or cannot be locked.
Biphase Coding 
Error
Red LED
Biphase coding of incoming date is 
incorrect.
Parity Error
Red LED
SRD stream’s parity bit is not set as 
specified.
CRC Error 
Red LED
The CRC value calculated for the 
incoming data does not match the CRC 
byte of the channel status word.
Confidence Flag 
Error
Red LED
The received data eye opening is less 
than a half-bit period, indicating a 
possible lack of signal strength or high 
jitter.
May also indicate that insufficient EA is 
applied.
Validity Error
Red LED
AES stream’s validity bit is high.
The incoming data is not suitable for 
conversion to an analog audio signal.
Alarm
Red LED
Indication that the external alarm 
contact closure is asserted, and this card 