SonicWALL Internet Security Appliances Benutzerhandbuch

Seite von 293
Page 248 SonicWALL Internet Security Appliance Administrator’s Guide
SonicWALL TELE3 TZX Back Panel l
SonicWALL TELE3 TZX Back Panel Description
Reset Switch 
Erases the firmware and resets SonicWALL TZX to its factory clean state. This can be necessary
if the administrator password is forgotten, or the firmware has become corrupt. 
Serial Port 
DB-9 RS-232 Serial port for Command Line Interface support. 
(6) Twisted Pair (10Base-T, 100Base-T) Ethernet Ports 
(6) Auto switching 10Mbps/100Mbps Ethernet ports provide connectivity for both Ethernet and
Fast Ethernet networks. The Ethernet ports connect the SonicWALL TZX to the WorkPort,
HomePort, and WAN using Twisted Pair cable with RJ45 connectors.
Power Input 
Connects to the external power supply that is provided with the SonicWALL TZX. The use of an
Uninterruptible Power Supply (UPS) is recommended to protect the SonicWALL TZX against
damage or loss of data due to electrical storms, power failures, or power surges. 
Reset Switch
WorkPort Ethernet Port
10Mbps/100Mbps
10Mbps/100Mbps
HomePort Ethernet Port
10Mbps/100Mpbs
5VDC,2A
Power input
WAN Ethernet Port
Serial Port