Cover plates
Remove the corresponding plates to install the optional
boards.
6 U
 (signal ground) terminal
For signal ground.  Connect to a ground wire as
required.
7
STATUS OUT connector (15-pin)
Outputs the following error statuses of the PFV-L10.
• The inserted optional board does not function
correctly.
• The temperature inside the unit has risen to a
specified level.
• Trouble occurs with the output voltage of power unit
A or B.
• The power is turned off.
• The ventilation fans have stopped rotating.
• A voltage overload has occurred.
Pin No.
Functions
1
Status output of the board inserted in slot 1.
Normal:  Low level
2
Status output of the board inserted in slot 2.
Normal:  Low level
3
Status output of the board inserted in slot 3.
Normal:  Low level
4
Status output of the board inserted in slot 4.
Normal:  Low level
5
Status output of the board inserted in slot 5.
Normal:  Low level
6
Status output of the board inserted in slot 6.
Normal:  Low level
7
Status output of the board inserted in slot 7.
Normal:  Low level
8
Status output of the board inserted in slot 8.
Normal:  Low level
9
Status output of the board inserted in slot 9
Normal:  Low level
10
Status output of the power unit B.
Normal:  Low level
11
Status output of the power unit A.
Normal:  Low level
12
Status output of the ventilation fans.
 Normal: Low level
13
Status output of the voltage load.
Normal:  Low level
14
Status output of board inserted in slot 10
Normal:  Low level
15
GND
8
~AC IN A connector
To supply power to power unit A, connect to an AC
power supply using an appropriate AC power cord.
9
~AC IN B connector
To supply power to power unit B, connect to an AC
power supply using an appropriate AC power cord.