Enterasys Networks 9033900-04 Benutzerhandbuch

Seite von 316
Command Groups
RoamAbout Access Point 3000 Configuration Guide
A-41
sntp-server date-time
This command sets the system clock.
Default Setting 
00:00:00, January 1, 1970
Command Mode 
Global Configuration
Example 
This example sets the system clock to 14:37 January 18, 2004:
Related Commands
Notes:
• The SNTP server must be disabled to set the date and time.
• The date and time is not saved after a reset. 
RoamAbout 3000#configure
Enter configuration commands, one per line. End with CTRL/Z
RoamAbout 3000(config)#sntp-server date-time
Enter Year<1970-2100>: 2004
Enter Month<1-12>: 1
Enter Day<1-31>: 18
Enter Hour<0-23>: 14
Enter Min<0-59>: 37
RoamAbout 3000(config)#