Gateway 9315 Benutzerhandbuch

Seite von 168
128
www.gateway.com
Environmental specifications
The following specifications identify maximum environmental conditions. At no time 
should the server run under conditions which violate these specifications.
Variable
Requirements
Temperature
Maximum rate of change: 18°F (10°C) per hour
Nonoperating: -40° to 158°F (-40° to 70°C)
Operating: 50° to 95°F (10° to 35°C); derated 0.9°F (0.5°C) for every 
1,000 feet (305 meters). Use of 2 GB DIMMs derates the server to 
86°F (30°C)
Altitude
10,000 feet (3,048 meters) maximum
Humidity
Nonoperating: 90% relative (noncondensing) at 86° F (30° C)
Shock
Operating - 2.0 g, 11 msec, 1/2 sine
Packaged - operational after an 18” fall
Electrostatic 
discharge (ESD)
Tested to 15 kilovolts (kV); no component damage