Juniper Networks M10i Benutzerhandbuch

Seite von 240
speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras
av den auktoritet som ansvarar för området.
Preventing Electrostatic Discharge Damage
Many router hardware components are sensitive to damage from static electricity.
Some components can be impaired by voltages as low as 30 V. You can easily
generate potentially damaging static voltages whenever you handle plastic or foam
packing material or if you move components across plastic or carpets. Observe the
following guidelines to minimize the potential for electrostatic discharge (ESD)
damage, which can cause intermittent or complete component failures:
Always use an ESD wrist strap or ankle strap, and make sure that it is in direct
contact with your skin.
CAUTION: For safety, periodically check the resistance value of the ESD strap. The
measurement should be in the range of 1 to 10 Mohms.
When handling any component that is removed from the chassis, make sure the
equipment end of your ESD strap is attached to one of the electrostatic discharge
points on the chassis, which are shown in 
.
Avoid contact between the component and your clothing. ESD voltages emitted
from clothing can still damage components.
When removing or installing a component, always place it component-side up
on an antistatic surface, in an antistatic card rack, or in an electrostatic bag (see
). If you are returning a component, place it in an electrostatic bag
before packing it.
140
Safety Guidelines and Warnings
M10i Internet Router Hardware Guide