Polycom 4300T Benutzerhandbuch

Seite von 118
User Guide V
2
IU 4300T Converged Network Appliance
3 - 48
1.
Log into the V
2
IU appliance using a Netscape or Internet Explorer web 
browser.
2.
Select System.
3.
Select Survivability.
4.
Enter the desired values for Time between heartbeat messages, Time to 
declare heartbeat lost, Number of lost messages to declare alarm and 
Number of received messages to clear alarm in the Softswitch 
Reachability section of the web page. 
5.
Press Submit.
The reachability settings are used to determine when the V
2
IU appliance 
provides local call switching by entering fallback mode and when it returns 
call control to network based call processing servers.  The definitions of the 
reachability settings are as follows:
Time between heartbeat messages - The number of seconds between each 
heartbeat message sent to the call processing servers to determine 
connectivity.
Time to declare heartbeat lost – The number of seconds that the V
2
IU appliance 
will wait before declaring a response to a heartbeat message lost.
Number of lost messages to declare alarm - the number of consecutively lost 
responses to heartbeat messages required for the V
2
IU appliance to declare a 
loss of connectivity to the network based call processing server.
Number of received messages to clear alarm - the number of consecutively 
received responses to heartbeat messages required for the V
2
IU Appliance to 
declare successful connectivity to the network based call processing server.
The formula used to determine the maximum time for the V
2
IU appliance to 
declare a loss of connectivity to a call processing server is:  maximum time = 
(X * Y) + Z, where,
X = Time between heartbeat messages
Y = Number of lost messages to declare alarm
Z = Time to declare a heartbeat lost
The default value for X, Y and Z in the V
2
IU appliance is 5.  Therefore, the 
default maximum time to declare a call processing server unreachable is 30 
seconds or ((5*5) + 5).
Step 3 - Specify the number of digits to use for local dialing
This field is the number of digits that the V
2
IU appliance will use for dialing 
when providing local call switching. By default the V
2
IU appliance will use 4, 
7 and 10 digit dialing.  Please follow the steps below if you would like to use a 
different number of digits:
1.
Log into the V
2
IU appliance using a Netscape or Internet Explorer web 
browser.