Brocade Communications Systems 53-1002373-02 Benutzerhandbuch

Seite von 452
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
233
53-1002373-02
Verifying proper operation
3
Syntax: show module
The Status column shows the module status. The management module status can be one of the 
following:
ACTIVE – The module is currently the active management module.
STANDBY – The module is currently the standby management module.
COMING UP – The module is coming up as the standby module. This status occurs if the 
standby management module becomes the active module during a switchover.
The switch fabric module status can be one of the following:
ACTIVE – The module is up and running.
BAD – The management module cannot initialize the switch fabric module.
An interface module status can be one of the following:
CARD_STATE_INIT – The system detects the module but the module is not up and running yet.
CARD_STATE_BOOT – The module is booting.
CARD_STATE_INTERACTIVE – The module is booting from interactive mode.
CARD_STATE_LP_SYNC – The software images are synchronized between the management 
module and interface module.
CARD_STATE_SYNC – The system is currently synchronizing the software image between the 
management module and interface module.
CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.
CARD_STATE_POWER_OFF – The module does not have power.
CARD_STATE_UP – The module is operating normally.
CARD_STATE_FAILED – The management module was unable to bring up an interface module. 
If you see this status, make certain that the interface module is installed properly. For more 
information, refer to 
CARD_DOWN_REASON_<explanation> – The module is in a nonfunctional state. This status 
appears with an explanation for why the module is down. For example, 
"CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve the 
problem, contact technical support and provide the explanation included with this status.
Brocade# show module
        Module                             Status      Ports Starting MAC
M1 (upper): Brocade router Mgmt Module        Active
M2 (lower):
F0: Brocade router Switch Fabric Module       Active
S1:
S2:
S3:
S4: Brocade router 4-Port 10Gig Module       CARD_STATE_UP   4   000c.db80.0000
S5: Brocade router 4-Port 10Gig Module       CARD_STATE_UP   4   000c.db80.0000
S6: Brocade router 4-Port 10Gig Module       CARD_STATE_UP   4   000c.db80.0000
S7:
S8: