Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
237
53-1002373-02
Installation precautions
4
CAUTION
Use a separate branch circuit for each AC power cord, which provides redundancy in case one of 
the circuits fails.
DANGER
Make sure to choose the appropriate circuit device, depending on the number of AC power 
supplies installed in the router. 
DANGER
Disconnect the power cord from all power sources to completely remove power from the router. 
DANGER
Make sure that the power source circuits are properly grounded, then use the power cord 
supplied with the router to connect it to the power source.
DANGER
If the installation requires a different power cord than the one supplied with the router, make 
sure you use a power cord displaying the mark of the safety agency that defines the regulations 
for power cords in your country. The mark is your assurance that the power cord can be used 
safely with the router.
DANGER
Make sure the rack or cabinet housing the router is adequately secured to prevent it from 
becoming unstable or falling over.
DANGER
Mount the routers you install in a rack or cabinet as low as possible. Place the heaviest router at 
the bottom and progressively place lighter routers above.